Cleaning the interior of the device – PHS/Multi PHS
ATTENTION!
- – Operate only when the power is off! Switch on the E-STOP button on the Control Panel to cut off power from the internal components of the machine.
- – For this operation, the vacuum cleaner must be completely disconnected from the PHS (suction and power).
- Using a 5 mm Allen key, unscrew the Service access panel to the Powder feeding screw (right side of the device). The panel holds 4 screws.
- Remove the Antistatic hose from the connector on the device.
- Connect a PVC brush to the end of the Antistatic hose vacuum cleaner.
- Check the grounding of the ATEX Vacuum Cleaner.
- Turn on the vacuum cleaner and clean the interior of the device. ATTENTION! While vacuuming, pay attention to the electrical installation and grounding!
- Treat the contents of the vacuum cleaner as waste for disposal.
- After vacuuming, install the panel back in place with screws.
- Remove the PVC brush from the end of the Antistatic hose.
- Connect the Antistatic hose back to the connector in the PHS.
- Reconnect the Vacuum cleaner power supply to the PHS.
- Reconnect the PHS to the power supply.
- Unlock the E-STOP button.
- Well done. The device is ready for further use.