Replacement of feed bed isolation

Every time you change from a lower melting point material to a higher melting point material you should swap the seal cords.

You will need: Sinterit Lisa (PRO) Feed Bed Sealing Kit, rubber gloves, a stainless steel probe and a plastic spatula.

  1. Turn on the printer and open the lid
  2. Turn the printer off and unplug the power cord.
  3. Remove the four screws that hold the feed bed plate in place.
  4. Using the probe, remove the old seals.
  5. Install bottom layer of seal – it consists of four short layers of rope.
  6. The second layer consists of one long loop. The end should meet near the hinges